CCTV FOV & Lens Calculator

Last reviewed: by Sarwar Islam

📹 Learning path · Step 7 of 18
CCTV: Zero to Designer

Pick a sensor, resolution and lens, enter how far away and how high the camera is, and see the field of view, pixel density and DORI distances at once. The lens finder works the other way round: tell it the detail you need at the target and it suggests the focal length. A worked entrance example and the method behind the numbers follow below the calculator.

CCTV Lens & Field of View Calculator

Field of view, pixel density, DORI distances, mounting tilt and blind zone, with a printable report.

Project: -
Camera: -
Date: -
Inputs: -
Notes: -
Camera
Installation
Lens finder
Report details (for PDF)
-
Horizontal FOV-
Scene width-
Pixel density-
Tilt / blind zone-
Pixel density at target
Detect 25Observe 62Recognise 125Identify 250
Top view: DORI coverage
IdentifyRecogniseObserveDetectBeyond detect
Side view: mounting & vertical FOV
DORI distances for this lens
LevelNeedsMax distanceScene width there
Lens recommendation

Uses nominal 16:9 (12MP: 4:3) active sensor sizes and the pinhole lens model; DORI thresholds per IEC 62676-4 (25 / 62 / 125 / 250 px/m). Real lenses vary by a few percent, and wide-angle lenses have barrel distortion. Distances are measured from the camera to the target (slant). Check final designs against the manufacturer's datasheet. Calculator by Techubox.com.

To download and print this tool without a watermark, please log in and request approval.

Choosing a CCTV lens by pixels, not by guesswork

“Will I see a face at the gate?” is a question about pixels per metre at the target, not megapixels. A 4 MP camera with a 2.8 mm lens and the same camera with a 6 mm lens give very different answers at 8 metres. This calculator turns sensor size, resolution, focal length and the mounting geometry into the numbers a design review asks for: horizontal and vertical field of view, scene width, pixel density, tilt angle, blind zone under the camera and the distance at which each DORI level ends. It is written for installers choosing lenses on site, designers preparing camera schedules and clients checking a proposal.

How to use it

  1. Select the sensor format and resolution from the camera datasheet.
  2. Enter the focal length; for a varifocal, try both ends.
  3. Enter the horizontal distance to the target, the camera height and the aim height (1.5 m is roughly face height).
  4. Read the coloured banner: the level you reach at that distance and the pixel density behind it.
  5. Use the lens finder: choose the level you need, or type the scene width you want to cover, and read the recommended focal length and lens type.
  6. Add the project and camera ID, then print or save the report as a PDF.

Worked example: a 4 MP camera with a 6 mm lens at a pedestrian entrance

A 4 MP (2560 × 1440) camera with a 1/2.8″ sensor and a fixed 6 mm lens is mounted at 3 m and aimed at face height (1.5 m) across a doorway 8 m away, measured horizontally.

Output Result
Slant distance to the target 8.14 m
Field of view (H × V) 50.3° × 29.6°
Scene at the target 7.64 m wide × 4.30 m high
Pixel density 335 px/m (102 px/ft): Identify
Tilt / blind zone 10.6° down, 6.31 m blind zone at ground level
DORI limits with this lens Identify 10.9 m, Recognise 21.8 m, Observe 44.0 m, Detect 109 m
Lens finder, Identify at 8.14 m 4.48 mm minimum, so a fixed 4–6 mm lens

The 6 mm lens gives about a third more pixels than identification needs, a sensible margin for night noise and compression. The trade-off is width: 7.64 m may not cover a wide lobby, so a varifocal set nearer 4.5 mm may suit better. Change the goal to plate reading (about 500 px/m) and the same camera only reaches 5.46 m; reading plates at 8.14 m needs about 8.95 mm, which points to a 2.8–12 mm varifocal.

The formulas behind the numbers

  • Slant distance = √(horizontal distance² + (camera height − aim height)²)
  • Horizontal FOV = 2 × atan(sensor width ÷ (2 × focal length))
  • Scene width = sensor width × slant distance ÷ focal length
  • Pixel density (px/m) = horizontal pixels ÷ scene width
  • Maximum distance for a level = horizontal pixels × focal length ÷ (sensor width × required px/m)
  • Focal length for a level = sensor width × distance × required px/m ÷ horizontal pixels

The tool uses the pinhole lens model with nominal 16:9 active sensor sizes (4:3 for 12 MP) and the DORI thresholds of 25, 62, 125 and 250 px/m. Distances are measured along the line of sight.

Design tips and common mistakes

  • Design to the level, not to the camera. Write “Identify at the turnstiles” in the brief, then let the pixel density pick the lens.
  • Keep the tilt small where faces matter. A steep camera sees the tops of heads and caps; mount lower or step the camera back.
  • Check the blind zone: floor area closer than it is out of view.
  • Do not stretch varifocal cameras to the long end at night. The IR illuminator and lens aperture often limit the real range before the pixels do. The lens selection guide covers aperture and IR in more detail.
  • Allow for barrel distortion on very wide lenses: image edges are weaker than the centre figure.

Limits of the calculator

Pixel density is a geometric figure. It does not model lighting, shutter speed, motion blur, compression, lens sharpness, WDR or the camera’s image processing, all of which decide whether a face is usable. Treat the result as a design baseline, confirm critical views on site with a test target, and check final values against the manufacturer’s datasheet. For laying out several cameras on a drawing, use the CCTV floor plan designer; for mounting heights and angles in practice, see the camera placement guide.

Standards notes

IEC 62676-4 (published in Europe as EN 62676-4) gives guidance on defining operational requirements and the pixel densities associated with observation categories. The classic DORI bands used here are a widely used simplification; the newer edition of IEC 62676-4 sets higher figures for some categories. Check which edition and which categories your project specification refers to, and any sector or local authority rules for the site.

Frequently asked questions

How many pixels per metre do I need to identify a face?

Most designs use about 250 px/m for identification under DORI and higher figures under IEC 62676-4. Check the level named in your project specification. In the example above, 335 px/m at 8.14 m clears the 250 px/m DORI threshold.

Why does a longer lens give better detail?

A longer focal length narrows the field of view, so the same number of pixels covers a smaller width and pixel density goes up. Going from 4 mm to 6 mm on the same 4 MP camera raises the identification limit from 7.28 m to 10.9 m.

Does mounting height matter?

Yes. A high camera looks down at a steep angle, so faces are seen from above. Keep the tilt small at entrances where you need identification. Height also lengthens the line of sight, which lowers pixel density slightly.

Is the result exact?

It is a design estimate. Lens distortion, lighting and compression change real image quality, so confirm critical views on site.

Up next in CCTV: Zero to Designer

Step 8: How to Calculate CCTV Storage

Watch the tutorial

CCTV FOV & Lens Calculator: step-by-step tutorial

CCTV FOV & Lens Calculator: step-by-step tutorial · More on YouTube @techubox

Scroll to Top