Design a complete CCTV system on your own floor plan: place IP and analogue AHD cameras, the NVR or DVR, PoE switches, SMPS power supplies, media converters, fibre patch panels and monitors, then draw every cable. The designer measures each run from the drawing scale, adds the drop to the camera and your slack, checks it against UTP, coax, PoE, channel, power and fibre limits, and builds the single line diagram, connection schedule and bill of quantities for you. A worked logistics-yard design and the rules behind every check are explained below the tool.

CCTV Designer

Load your own drawing (PDF, image, DXF or DWG), set the scale, place cameras, draw walls, and see IEC 62676-4:2025 or DORI coverage. Add NVR/DVR, switches, PoE, SMPS, fibre and monitors, link them with UTP, coax or fibre, and get cable lengths, checks, a single line diagram, schedule, BOQ and image export.

Drawing units
Set drawing scale
Real length between the two points:

New camera model

+ Custom model

Place devices & cables

Display

Cameras (0)

Export
Exported plan

How to use: 1) Load your floor plan (PDF, PNG, JPG, DXF or DWG). DXF/DWG set the scale from the drawing units, and you can hide layers such as furniture or text. 2) Set scale: click both ends of a known dimension and enter its length. 3) Draw walls so the coverage is cut where cameras can't see. 4) Add cameras, drag to move, drag the white handle to aim, and adjust focal length, mounting height and tilt (the grey sector is the blind zone under the camera). 5) Add NVR/DVR, switches, SMPS, media converters, ODFs and monitors, then use 🔗 Link to draw each cable: lengths come from the scale plus camera height and slack, and the Checks list flags UTP over 90/100 m, coax limits, PoE budget, channels, SMPS load, 12 V drop and fibre reach / loss. 6) Open the Single line diagram tab: it is drawn from your devices and links and prints with the plan, schedule and BOQ. Zoom with the mouse wheel or pinch; drag empty space to pan. Ranges use horizontal resolution, sensor width and focal length, corrected for mounting height (target at 1.5 m). They're a design baseline: lighting, compression and lens quality also matter. Your drawing stays in your browser. Techubox.com

 

From floor plan to single line diagram and BOQ

The CCTV Floor Plan Designer answers one question: what each camera can see. A real installation also needs every camera wired back to a recorder, powered, and checked against cable limits before anything is ordered. CCTV Designer adds that second half. Each camera keeps the same IEC 62676-4:2025 or DORI coverage bands, and every device and cable you draw feeds a connection schedule, a bill of quantities and a single line diagram that is redrawn automatically whenever the plan changes. It suits shops, offices, schools, warehouses, car parks and campuses where one drawing covers the system.

Step by step

  1. Load the drawing (PDF, PNG, JPG, DXF or DWG) and set the scale by clicking both ends of a known dimension. DXF and DWG files take their scale from the drawing units.
  2. Draw walls and shelving so coverage stops where a camera cannot see.
  3. Choose IP camera or Analog AHD camera and a model, press Add camera and click the drawing. Set the mounting height and, if you want, a fixed tilt. The grey sector under each camera is its blind zone.
  4. In Place devices & cables, pick a device type (NVR, DVR/XVR, PoE switch, network switch, media converter, fibre patch panel/ODF, SMPS or monitor), press Add device and click its location, usually the rack or a field cabinet.
  5. Press Link, click a camera or device, click any bend points along the cable route, then click the other end. Auto picks Cat6 for IP cameras, Siamese coax for AHD cameras, fibre to converters and ODFs, HDMI to monitors and power cable from an SMPS. You can change any cable in Selected link.
  6. Fix everything in Checks, open the Single line diagram tab, then save the project and print or export. The print contains the plan, camera schedule, single line diagram, connection schedule, BOQ and the list of checks.

Worked example: a logistics yard with a remote gatehouse

A warehouse has its rack in a ground-floor server room and a gatehouse 420 m away across the yard. A 2-channel analogue system is being kept on a separate DVR. The drawing is scaled at 1 px = 10 cm, the default slack is 10 % and every camera run includes the drop to the camera. The system:

  • Main building: NVR1 (16 channels), PoE1 (16 ports, 150 W, one 1G LX SFP), monitor on HDMI, and four 4MP Turret 4 mm IP cameras C1–C4 at 3 m.
  • Gatehouse: PoE2 (8 ports, 65 W, one 1G LX SFP) with a 4MP varifocal at 5 m (C5) and a 4MP PTZ at 6 m (C6, 25 W).
  • Fibre: PoE1 → ODF1 → 6-core single-mode OS2 trunk → ODF2 → PoE2, with 2-core patch cords at each end.
  • Analogue: two 2MP AHD bullets C7 and C8 on RG59 + power (Siamese) to an 8-channel DVR, powered from a 12 V 5 A SMPS in the rack.

The connection schedule the designer produces:

Link Cable Route Drop Length with 10 % slack Result
C1 → PoE1 UTP Cat6 30 m 3 m 37 m OK
C2 → PoE1 UTP Cat6 44 m 3 m 52 m OK
C3 → PoE1 UTP Cat6 60 m 3 m 70 m OK
C4 → PoE1 UTP Cat6 84.3 m 3 m 97 m Over the 90 m permanent link
ODF1 → ODF2 Fibre SM OS2, 6 core 419 m 0 m 461 m Channel 3.79 dB, 6.7 dB margin
C5 → PoE2 UTP Cat6 22.5 m 5 m 31 m OK
C6 → PoE2 UTP Cat6 28 m 6 m 38 m OK
C7 → DVR1 RG59 + power 56 m 3 m 65 m 12 V drop 1.36 V (11 %)
C8 → DVR1 RG59 + power 100 m 3 m 114 m 12 V drop 2.38 V (20 %)

Read it as the checks do. C4 is 97 m of cable: under the 100 m Ethernet channel but over the 90 m permanent link, so move PoE1’s patch panel closer, or feed C4 from a small switch. The gatehouse fibre channel runs from optic to optic through both ODFs: 469 m of fibre at 0.4 dB/km is 0.19 dB, four mated connectors at 0.75 dB add 3.0 dB and two fusion splices at 0.3 dB add 0.6 dB, so 3.79 dB against the 10.5 dB budget of a 1G LX module leaves 6.7 dB of margin, comfortably over the 3 dB to keep. PoE2 carries 31 W of a 65 W budget, PoE1 24 W of 150 W, and NVR1 records 6 of its 16 channels. The two AHD cameras are the real problem: at 0.5 A, the 18 AWG power pair in Siamese cable loses 1.36 V over 65 m and 2.38 V over 114 m, so C8 would see under 10 V at the camera. Give the yard cameras a local 12 V supply or a 24 V AC camera instead.

The bill of quantities for the same design lists 6 IP and 2 AHD cameras, NVR, DVR, both PoE switches, two ODFs, the SMPS, the monitor, two 1G LX SFP modules, 332 m of Cat6 (about two 305 m boxes), 179 m of Siamese, 461 m of 6-core and 8 m of 2-core OS2 fibre, two fusion splices and 12 LC connectors.

How lengths and checks are calculated

  • Cable length = (route on the plan + camera mounting height + extra) × (1 + slack %), rounded up to the next metre. Any length can be overridden by hand.
  • UTP: warning above 90 m (permanent link), error above 100 m (channel incl. patch cords), per TIA-568 / ISO/IEC 11801.
  • AHD on RG59 coax: typical reach 500 m for 1080p, 400 m for 4–5 MP, 300 m for 8 MP. AHD over UTP with passive baluns: 250 m (1080p) and 200 m (4 MP+). Vendor limits differ, so check the datasheet.
  • 12 V drop = camera current × 2 × length × resistance per conductor (20.9 mΩ/m for the 18 AWG pair in Siamese cable, 19.5 mΩ/m for 2 × 1.0 mm² power cable). Warning above 10 %, error above 20 %.
  • PoE: sum of the IP camera power on each PoE switch or PoE NVR against its budget (warning above 90 %), plus port, SFP slot and built-in PoE port counts.
  • Recorders: IP cameras reached through switches, converters and ODFs count against NVR channels; AHD cameras against DVR channels and IP cameras against XVR IP channels. AHD to NVR, IP to DVR without IP channels, and IP cameras on coax are flagged.
  • SMPS: total camera current against the rating (warning above 80 % load) and the number of outputs.
  • Fibre channel loss = total length × attenuation (OS2 0.4 dB/km, OM3/OM4 3.5 dB/km) + 0.75 dB per mated connector pair + 0.3 dB per splice (TIA-568 maximum values), checked against the optic’s reach and power budget, with 3 dB recommended margin. Single-mode and multimode mixed on one channel, mismatched optics and cameras linked straight to fibre are errors.
  • Blind zone: tilt points the image centre at a 1.5 m target where the camera gives 125 px/m, unless you set the tilt. The ground is not visible closer than height ÷ tan(tilt + half the vertical field of view).

Practical tips

  • Set the scale before linking anything. Every cable length, fibre loss and voltage drop follows from it.
  • Draw cable routes along the containment with bend points, not straight across rooms. The straight line always under-measures. A cable drawn straight across a switch or other device it does not connect to is listed in Checks, because on the plan it looks connected: link it through that device if that is the real route. The single line diagram always follows the links you drew, hop by hop.
  • Put an ODF at each end of a fibre trunk and set the SFP module on each switch: the channel is checked optic to optic through the panels.
  • Keep AHD power runs short. Put the SMPS near the cameras and run only coax back to the DVR, or choose 24 V AC cameras for long runs.
  • Use the PoE Budget Calculator for detailed per-port PoE classes and the CCTV Storage Calculator to size the NVR disks.

What the designer does not model

Coverage is a plan view; glare, backlight, lighting levels, compression and lens sharpness are not modelled. Cable limits are typical values from the standards and common datasheets, not a substitute for the manufacturer’s figures. The voltage drop check covers 12 V DC camera supplies, not 24 V AC. Fibre loss uses worst-case connector and splice values and does not include patch-cord bends or ageing beyond the 3 dB margin. Confirm critical runs on site. The CCTV system design guide and the CCTV wiring guide for HD analogue and IP cameras cover the rest.

Standards notes

Coverage bands follow the observation categories of IEC 62676-4:2025 or the classic DORI densities (25, 62, 125 and 250 px/m). Copper limits follow the 90 m permanent link and 100 m channel of TIA-568 and ISO/IEC 11801; fibre connector and splice losses use the TIA-568 maximum values; PoE budgets follow IEEE 802.3af/at/bt as declared by the switch maker. Check the editions your specification cites and any client, insurer or authority requirements.

Frequently asked questions

How is this different from the CCTV Floor Plan Designer?

The CCTV Floor Plan Designer places cameras and shows their coverage. CCTV Designer keeps the same coverage and adds recorders, switches, power, fibre and monitors, the cables between them, design checks, a single line diagram and a bill of quantities.

Can I mix IP and analogue AHD cameras?

Yes. IP cameras connect over UTP to PoE switches or an NVR; AHD cameras connect over coax, Siamese or UTP with baluns to a DVR or hybrid XVR. The checks flag an AHD camera on an NVR or an IP camera on a DVR without IP channels.

How does it work out fibre loss?

It follows each fibre channel from one optic to the other through any patch panels, adds attenuation per kilometre, 0.75 dB per connector pair and 0.3 dB per splice, and compares the total with the reach and power budget of the SFP or media converter you selected.

Is my drawing uploaded to a server?

No. The file is processed in your browser, and the project autosaves in your browser too.