Exit Plan Designer

Last reviewed: by Sarwar Islam

🔥 Learning path · Step 14 of 14
Fire Alarm Engineer

Turn a floor plan into a printed evacuation plan: place ISO 7010-style safety signs, draw the main and alternative escape routes with direction arrows, and let the tool measure how far the nearest exit, extinguisher and call point are from “You are here”. The poster prints in English, Arabic or both. A worked office example and the checks the tool leaves to you are below.

Emergency Exit Plan Designer v1.1

Load a floor plan, place fire safety signs, draw escape routes with direction arrows, find the nearest extinguisher, hose reel and exit from “You are here”, then print a bilingual evacuation plan. By Techubox.com

1 · Floor plan

2 · Safety signs (tap a sign, then tap the plan)

3 · Escape routes

Route: tap points along the corridor from the room to the exit, then ✔ Finish (or double-tap). Arrows follow the direction you drew.

4 · Nearest from “You are here”

Straight-line distance, not walking distance. Set the scale for metres.

5 · Poster

Your work autosaves in this browser. Check the final plan against the site, the fire strategy and the local authority (in KSA, Civil Defense / SBC 801).

To download and print this tool without a watermark, please log in and request approval.

What a good evacuation plan has to do

An evacuation plan is read in a hurry by someone who may never have been on that floor before. It has to answer three questions within seconds: where am I, which way do I go, and what is near me if I need to raise the alarm or tackle a small fire. This designer is built around those questions. You load the floor drawing, mark the reader’s position, draw the routes and place the signs, and the tool produces an A3 or A4 poster with a bilingual legend, instructions and a list of the equipment nearest to the reader.

It suits safety officers preparing plans for each floor, facility managers replacing faded posters and fire contractors handing over plans with a system. Make one plan for each mounting position, because “You are here” changes with every poster.

Making a plan step by step

  1. Load the plan. Use a PDF page, an image, a DXF or a DWG, or start with a blank sheet. Fade the drawing or turn it grey so the signs stand out, as on printed evacuation plans.
  2. Set the scale. Press Scale, tap both ends of a known dimension and type the real length in metres. Without a scale the tool can still draw, but it cannot give distances.
  3. Place “You are here” where the poster will be mounted. There is only one per plan; placing it again moves it.
  4. Add the signs. Sixteen symbols are available, including emergency exit, escape stairs, assembly point, extinguisher, hose cabinet, call point, fire blanket, dry riser inlet, sprinkler valve, first aid, defibrillator, eye wash and “Do not use lift”. Add a label such as “FE-01, CO2 5 kg” under any sign.
  5. Draw the routes. Choose Exit route, tap points along the corridor from the reader towards the exit, then Finish. Draw a second, dashed route with Alternative route. Arrows follow the direction you drew.
  6. Finish the poster. Add the title in English and Arabic, building and floor, north arrow, logo and the instructions (one per line), then print or export a PNG. Save the project file for the next revision.

Worked example: distances from “You are here” on an office floor

The floor is 40 × 25 m, drawn on a blank sheet with the scale set to 40 px per metre. The poster hangs in the central corridor, 20 m from the west wall and 12 m from the north wall. The main exit is at the east end of the corridor and the escape stairs are in the north-west corner. With “Draw lines to the nearest equipment” ticked, the panel lists:

Nearest item Straight-line distance
Fire extinguisher (nearest of two) 5.0 m
Fire hose cabinet 6.0 m
First aid 10.0 m
Fire alarm call point, beside the exit door 17.0 m
Emergency exit 18.0 m
Escape stairs 19.7 m
Assembly point 22.5 m

Two things are worth noticing. The second extinguisher, 14.4 m away, is ignored because only the nearest of each type is listed. And the stairs look almost as close as the main exit, but the alternative route has to run 18 m along the corridor and then 8 m north, so the walking distance is about 26 m, not 19.7 m. If someone asks whether this floor meets a maximum travel distance, measure along the drawn route on the drawing, never from the straight-line figure.

How the distances are worked out

  • Distance = √(Δx² + Δy²) between “You are here” and each sign, in drawing pixels, multiplied by the metres per pixel from your scale.
  • For each type (exit, stairs, extinguisher, hose cabinet, call point, first aid, defibrillator, assembly point) only the closest sign is reported.
  • The same list is printed on the poster under “Nearest to you” when there is room on the sheet.

Practical tips

  • Turn the plan so that “ahead” on the poster is “ahead” for the person reading it on the wall. A plan that has to be mentally rotated slows people down.
  • Show routes to two independent exits wherever the building has them.
  • Draw only what helps escape. Hide furniture, dimension and text layers from a DXF or DWG.
  • Check every sign on site. Extinguishers and hose reels get moved during fit-outs, and an out-of-date plan is worse than none.
  • Match the plan to the fire alarm layout so call points on the poster are the ones on the wall. The Fire Alarm Design Tool and the guide on how to design a fire alarm system cover call point positions.

Limits

The tool does not know where walls, doors or obstructions are, so it cannot find a route for you, check travel distance, dead ends or exit width, or decide where equipment must go. Those come from the fire strategy for the building. For tall buildings with phased evacuation, see fire alarm design for high-rise buildings before deciding what the plan should tell occupants.

Standards note

ISO 7010 gives guidance on safety sign symbols, and ISO 23601 gives guidance on the layout and content of escape and evacuation plans, including colours and orientation. Local rules vary: in Saudi Arabia the Civil Defense and SBC 801 apply. Check the current edition and the requirements of your local authority or AHJ before the plans are printed and fixed.

Frequently asked questions

Are the signs official ISO 7010 artwork?

They are drawn in ISO 7010 style. Check the final plan against your fire strategy and local authority requirements.

Can I make the plan in Arabic?

Yes. The poster header, legend and instructions are bilingual, Arabic and English. You can also print the legend in English only or Arabic only.

What colour should escape routes be?

Green is the common convention for escape routes. You can switch to red if your client or authority asks for it.

Is the distance shown the travel distance?

No. It is the straight-line distance from “You are here”. Walking distance along the corridors is always the same or longer.

Last step of Fire Alarm Engineer 🎉

Mark it complete to finish the path.

Watch the tutorial

Emergency Exit Plan Designer: step-by-step tutorial

Emergency Exit Plan Designer: step-by-step tutorial · More on YouTube @techubox

Scroll to Top